PROTECTOR
   THERMOSTAT
   OTHERS
 
 
    THERMOSTAT


HB-5

Applications
- Refrigerator
- Electrical Blanket
- Showcase
- Ice Machine
- Electrical Stove
Features
- Ultra slim type
- Ideal for where space is premium
- Plastic seal available for hermetic protection
- Leadwire and terminal can be attached upon order
- Double contacts for extra reliability
- UL, SEMKO and CSA recognized
Specifications
- Electrical Ratings
15A / 125V AC
7.5A / 250V AC
- Operating Temperature Range
-20°c ~ 150°c
- Life Cycles 100,000 Cycle
Untitled Document
  THERMOSTAT
  HB-2
  HB-21
  HB-5
  HB-31
  HB-32
  HB-51
  HB-33 (pdf)
 
Selection Code Chart

1. Operation Type  
Contact Operation
Code A
Code B
Open on Rise
Close on Rise
2. Electric Raring
Code R
Code X
Code D
7.5A, 250V AC
1A fewer (Cross Bar contact)
8A, 12V DC
3. Cap Type
Code R
4. Bracket Type
Code N
5. Terminal Type
Code C
Code D


Code SH
Code SV


6. Top Temperature in °c
Temperature Range
-20°c to 100°c
101°c to 120°c
121°c to 150°c
Differential
10°c
15°c
20°c
7. Top Temperature Tolerance Code
Temperature Range
-20°c to 100°c
101°c to 120°c
121°c to 150°c
 
3°c
Differential
10°c
15°c
20°c
8. Bottom Temperature in °c
Temperature Range
-20°c to 100°c
101°c to 120°c
121°c to 150°c
Differential
10°c
15°c
20°c
9. Bottom Temperature Tolerance Code
Temperature Range
-20°c to 100°c
101°c to 120°c
121°c to 150°c
 
3°c
Differential
10°c
15°c
20°c